请输入您要查询的英文单词:

 

单词 correlator
释义

correlator


cor·re·late

C0659700 (kôr′ə-lāt′, kŏr′-)v. cor·re·lat·ed, cor·re·lat·ing, cor·re·lates v.tr. To establish or demonstrate as having a correlation: correlated drug abuse and crime.v.intr. To be related by a correlation.adj. (-lĭt, -lāt′) Related by a correlation, especially having corresponding characteristics.n. (-lĭt, -lāt′) Either of two correlate entities; a correlative.
[Back-formation from correlation.]
cor′re·lat′a·ble adj.cor′re·la′tor n.

correlator

(ˈkɒrɪˌleɪtə) n (Tools) a device that locates leaks in water or gas lines through noise detection
IdiomsSeecorrelate

Correlator


correlator

[′kär·ə‚lād·ər] (electronics) A device that detects weak signals in noise by performing an electronic operation approximating the computation of a correlation function. Also known as correlation-type receiver.

Correlator

 

(correlation-type receiver), an instrument used to measure the correlation functions of random processes. A knowledge of the correlation coefficient permits an analysis to be made of physical phenomena having probabilistic characteristics, such as the noise in radio receiving apparatus, cosmic particle showers, and biopotentials (see). When two random signals in the form of AC electrical voltages U1(t) and U2(t) are supplied to the inputs of a correlator, its output voltage is proportional to the cross-correlation function of these signals. If a signal Uc(t) is supplied to both inputs, the correlator measures the autocorrelation coefficient.

Electronic correlators are the most widely used. The indicator is usually a pointer-type instrument calibrated in terms of the correlation coefficient, or a cathode-ray tube. Provision is usually made for the connection to a digital or a chart recording system. Correlators are employed in radio-communication devices (to measure the transient attenuations in multi-channel systems); in radar, sonar, and radio astronomical equipment (for correlation direction finding and to improve the resolution of transmission); and in medical diagnostic equipment. The signals studied in a cross-correlation have frequencies ranging from 1 Hz to 50 MHz. Special signal-processing methods are used to raise the signal frequency factor to 500 MHz. The measuring gauge for the correlation coefficient ranges from 0.01 to 1, and the error of the correlator is between 5 and 10 percent.

REFERENCES

Lange, F. Korreliatsionnaia elektronika. Leningrad, 1963. (Translated from German.)
Mirskii, G. la. Radioelektronnye izmereniia, 2nd ed. Moscow, 1969.
Valitov, R. A., and V. N. Sretenskii. Radiotekhnicheskie izmereniia. Moscow, 1970.

E. G. BILYK

随便看

 

英语词典包含2567994条英英释义在线翻译词条,基本涵盖了全部常用单词的英英翻译及用法,是英语学习的有利工具。

 

Copyright © 2004-2022 Newdu.com All Rights Reserved
更新时间:2024/11/14 17:01:50